Digital Multimeter Fluke Digital Multimeter - Fluke F117 117C 117 Price.....................$245 Item specifics Model Number:117 Brand Name:Fluke Maximum voltage:600 V Surge protection:6 kV peak per IEC 61010-1... Fuse for A input:11 A, 1000 V FAST Fuse (F... Display:6,000 counts, updates 4 p... Bar graph:33 segments, updates 32 p... Operating Temperature:-10 °C to + 50 °C Storage Temperature:-40 °C to + 60 °C Specifications: Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Fuse for A input 11 A, 1000 V FAST Fuse (Fluke PN 803293) Display Digital:6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second Operating Temperature -10 °C to + 50 °C Storage Temperature -40 °C to + 60 °C Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery Life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range: 600.0 mV Resolution: 0.1 mV Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
DC volts Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.00 V / 0.1 V Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
Auto volts Range: 600.0 V Resolution: 0.1 V Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms Range: 600.0 mV Resolution: 0.1 mV Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.0 V / 0.1 V Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)
Continuity Range: 600 Resolution: 1 Accuracy: Beeper on < 20 , off > 250 ; detects opens or shorts of 500 s or longer.
Ohms Range/Resolution: 600.0 / 0.1 Range/Resolution: 6.000 k / 0.001 k Range/Resolution: 60.00 k / 0.01 k Range/Resolution: 600.0 k / 0.1 k Range/Resolution: 6.000 M / 0.001 M Accuracy: 0.9 % + 1 Range/Resolution: 40.00 M / 0.01 M Accuracy: 5 % + 2
Diode Test Range/Resolution: 2.000 V / 0.001 V Accuracy: 0.9% + 2
Capacitance Range/Resolution: 1000 nF / 1 nF Range/Resolution: 10.00 F / 0.01 F Range/Resolution: 100.0 F / 0.1 F Range/Resolution: 9999 F / 1 F Range/Resolution: 100 F to 1000 F Accuracy: 1.9% + 2 Range/Resolution: > 1000 F Accuracy: 5% + 20%
LoZ capacitance Range: 1 nF to 500 F Accuracy: 10% + 2 typical
AC amps true-rms (45 Hz to 500 Hz) Range/Resolution: 6.000 A / 0.001 A Range/Resolution: 10.00 A / 0.01 A Accuracy: 1.5% + 3 20 A continuous overload for 30 seconds max
DC amps Range/Resolution: 6.000 A / 0.001 A Range/Resolution: 10.00 A / 0.01 A Accuracy: 1.0% + 3 20 A continuous overload for 30 seconds max
Hz (V or A input)2 Range/Resolution: 99.99 Hz / 0.01 Hz Range/Resolution: 999.99 Hz / 0.1 Hz Range/Resolution: 9.999 Hz / 0.001 Hz Range/Resolution: 50.00 Hz / 0.01 Hz Accuracy: 0.1% + 2 Mechanical & General Specifications Size 167 x 84 x 46 mm (6.57'' x 3.31'' x 1.82'') Weight 550 g Includes: •1 X F117C •1 X pair of leads •1X manual For details and other similar equipment, please visit our equipment website: http://www.sourceindustrialsupply.com |